Utilize este identificador para referenciar este registo: http://hdl.handle.net/10400.9/1067
Título: Solar XXI building PV systems: performance during the first two yeras of operation
Autor: Rodrigues, Carlos
Viana, Susana
Joyce, António
Gonçalves, Helder
Silva, António Rocha e
Palavras-chave: BIPV
Grid connected PV systems
PV micro-generation
Data: 7-Out-2008
Citação: Rodrigues, C.;Viana, S.; Joyce, A.; Gonçalves, H.; Silva, A. R. Solar XXI building PV systems: performance during the first two yeras of operation. In: Eurosun 2008 - 1st International Conference on Solar Heating, Cooling and Buildings, Lisbon, Portugal, 7th - 10th October 2008
Resumo: The purpose of this paper is to present the results obtained in the first two years of operation of the grid-connected photovoltaic (PV) systems installed in the named “Solar XXI” building. One PV system, made with multicrystalline silicon modules, has a peak power of 12 kW and was installed on the façade; another system made with amorphous silicon modules has a peak power of 6 kW and was installed in the surrounding park area near the building. From 1st February 2006 until 31 July 2008, the measured daily average, of the building electrical energy consumption, was about 75 kWh and the two PV systems produced in average about 72 % of this energy. The averaged measured Performance Ratio of the systems was about 0.84 for the PV Façade and about 0.76 for the PV in the Park.
URI: http://hdl.handle.net/10400.9/1067
Aparece nas colecções:UEAC - Comunicações em actas de encontros científicos internacionais

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
SOLARXXIPVSYSTEMS.pdf421,63 kBAdobe PDFVer/Abrir


FacebookTwitterDeliciousLinkedInDiggGoogle BookmarksMySpace
Formato BibTex MendeleyEndnote Degois 

Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.