Percorrer por data de Publicação, começado por "2026-08"
A mostrar 1 - 1 de 1
Resultados por página
Opções de ordenação
- Inter-equipment ongoing validation of microplastic identification by micro-FTIR using optimal resourcesPublication . Fernandes, Rafaela; Miclea, Paul-Tiberiu; ROSSI, Andrea Mario; Giovannozzi, Andrea M.; Putzu, Mara; Morgado, Vanessa; Palma, Carla; Almeida, José Miguel; Pedro, Matilde São; Drago, Claudia; Quendera, Raquel Maria Pina Amaral; Pellegrino, Olivier; Bettencourt da Silva, RicardoABSTRACT: FTIR is widely used for identifying microplastics due to its performance and affordable equipment. However, there is a need for a universal method for the automatic identification of microplastics by FTIR, robust to different spectra collection conditions, and capable of adapting to the diversity of particle spectra. This research presents a method for developing a reliable and simple algorithm for inter-instrumental microplastic identification using micro-FTIR. Spectra collected from different equipments and settings across various laboratories, from microparticles previously confirmed as PET (positive cases) and non-PET (negative cases), were compared with a PET reference using multiple algorithms (match methods) based on six weighted and unweighted correlation coefficients. After excluding low signal-to-noise spectra with a newly developed universal algorithm, the 5th percentile of the match values for positive cases, estimated using a robust bootstrap method, was used as a minimum match (P5 & raquo;P) to ensure a 95% true positive rate (TP). Assuming a normal distribution of the match values for negative cases, the false positive rate (FP) was calculated. The best method identified uses an unweighted correlation of differentiated signals, resulting in a P5 & raquo;P = 0.4140 and FP = 0.0005% for spectra with a minimum signal-to-noise ratio of three. This identification performance, estimated from 117 spectra, is statistically equivalent to that observed from the identification of 405 additional particles using the validated method, at a 99% confidence level set by the Clopper-Pearson method, thereby extending the method's applicability to 522 particles. The developed method for PET identification by FTIR is robust across various acquisition conditions and instruments, was implemented in a user-friendly MS Excel spreadsheet, and can be easily tested with more particles and different instrumental settings. The validity of the identification algorithm and the defined criteria cannot be extrapolated to a different reality with respect to spectral collection conditions and the diversity of negative cases without a prior performance assessment.
