Thermal performance of residential buildings with large glazing areas temperature climate

dc.contributor.authorTavares, Márcia
dc.contributor.authorGoncalves, Helder
dc.contributor.authorBastos, Jorge
dc.date.accessioned2010-05-31T09:00:16Z
dc.date.available2010-05-31T09:00:16Z
dc.date.issued2010-03-17
dc.description.abstractThis work presents the results of an experimental and numerical study of a residential buildings in a temperature climate, the paticularity of these bulding the large glazing areas around 65% to 85% of exterior façade. The thermal performance is presented and dicussed. The study was developed taking into account the implementation of monitoring during the summer and winter for a housing unit in an intermediate floor with only one façade in contact with the exterior (south façade) without solar protection by the glass (glazing area 80% exterior façade) located in Lisbon, Portugal (Latitude 40º N9; as well as detailed modeling of this unit using EnergyPlus for thermal simulation. The detailed model took into account the characteristics of the housing unit and the conditions under which it was monitored during the summer and winter. To simulate the detailed model under the monotored conditions the climatic data was cerefully introduced in the thermal simulation (climate file), the data was obtaines from the metereological stations of the National Laboratory for Energy and Geology (LNEG, Lisbon) for the same periods of the monitoring. From the detailed model different parametric variations were performed (summer and winter). Thus we obtained a set of effects that let you chek the parameters of major and minor influence on the thermal performance of housing units with large glazing areas situated in temperate climates. This work intends to provide tools and guidance to building designers with regard to the thermal performance of buildings.pt
dc.identifier.citationTavares, Márcia. Gonçalves, Helder; Bastos, Jorge. Thermal performance of residential buildings with large glazing areas temperature climate. Comunicação apresentada na Conferência: Portugal SB10: Sustainable Buildings Affordable to All: Low Cost Sustainable Solutions, Vilamoura, Algarve, Marçol 17-19, 2010, p. 647-654pt
dc.identifier.urihttp://hdl.handle.net/10400.9/662
dc.language.isoengpt
dc.subjectEficiência energéticapt
dc.titleThermal performance of residential buildings with large glazing areas temperature climatept
dc.typeconference object
dspace.entity.typePublication
oaire.citation.conferencePlaceVilamoura, Algarvept
oaire.citation.titlePortugal SB10: Sustainable Buildings Affordable to All: Low Cost Sustainable Solutionspt
person.familyNameGoncalves
person.givenNameHelder
person.identifier.ciencia-id0D10-5608-8BD5
person.identifier.orcid0000-0002-7350-263X
person.identifier.scopus-author-id7003936553
rcaap.rightsopenAccesspt
rcaap.typeconferenceObjectpt
relation.isAuthorOfPublication5df6a8f0-604f-4d27-ab9c-3f97d991849c
relation.isAuthorOfPublication.latestForDiscovery5df6a8f0-604f-4d27-ab9c-3f97d991849c

Files

Original bundle
Now showing 1 - 2 of 2
Loading...
Thumbnail Image
Name:
THERMALPERFORMANCESB10.pdf
Size:
1.01 MB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
Apresentaç¦o SB10 Márcia Tavares.pdf
Size:
911.27 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.8 KB
Format:
Item-specific license agreed upon to submission
Description: